Search results for "Magnesium nitrate"

showing 3 items of 3 documents

Sodium nitrate and tungsten as matrix modifiers for the determination of arsenic in shotgun pellets by electrothermal atomic absorption spectrometry

2001

A method for the determination of arsenic in a complicated sample matrix by Zeeman effect electrothermal atomic absorption spectrometry using tungsten and sodium nitrate as matrix modifiers was developed. The determination of arsenic in SRM C2416 (Bullet Lead) and SRM 2710 (Montana Soil) by ETAAS using a mixture of palladium and magnesium nitrate as a matrix modifier failed to obtain the certified concentrations at the 95% level of confidence using the t-test. Both tungsten and sodium nitrate as matrix modifiers stabilized arsenic so that the certified concentrations of the SRMs were determined with high accuracy and precision (RSD   0.999), with low detection and quantification limits, wer…

ChemistryAnalytical chemistryPelletschemistry.chemical_elementTungstenAnalytical Chemistrylaw.inventionMatrix (chemical analysis)Magnesium nitratechemistry.chemical_compoundlawSodium nitrateStandard additionAtomic absorption spectroscopySpectroscopyArsenicJ. Anal. At. Spectrom.
researchProduct

Water vapour pressure above saturated salt solutions at low temperatures

1999

Abstract The properties of water–salt systems in relation to their vapour pressure are studied especially at low temperature. The water vapour pressure of saturated salt solutions of strontium chloride, zinc chloride, nickel chloride, nickel nitrate, magnesium chloride, magnesium bromide, magnesium nitrate, calcium chloride, potassium nitrite, lithium chloride, lithium bromide, lithium iodide and sodium bromide are measured in a temperature range −40 to +10°C. The apparatus used in this study, is well adapted to measure very low pressure with an uncertainty of pressure measurement of 2% for a range between 10−3 and 10 mm Hg. The experimental values are fitted by Antoine equation with mean p…

Lithium bromideVapor pressureMagnesiumGeneral Chemical EngineeringInorganic chemistryStrontium chlorideGeneral Physics and Astronomychemistry.chemical_elementChloridechemistry.chemical_compoundMagnesium nitrateSodium bromidechemistrymedicineLithium chloridePhysical and Theoretical Chemistrymedicine.drugFluid Phase Equilibria
researchProduct

Some observations on the use of matrix modifiers in the determination of aluminum by electrothermal atomic absorption spectrophotometry

1989

Abstract Some evidence demonstrating that the use of matrix modifiers is necessary to obtain good calibration lines in the determination of aluminum by graphite furnace atomic absorption spectrophotometry is provided. It was found that the most sensitive results were obtained when Mg(NO 3 ) 2 was used instead of NH 4 H 2 PO 4 .

medicine.diagnostic_testAnalytical chemistrychemistry.chemical_elementAnalytical Chemistrylaw.inventionMatrix (chemical analysis)Magnesium nitratechemistry.chemical_compoundchemistryAluminiumlawSpectrophotometrymedicineCalibrationGraphite furnace atomic absorptionAtomic absorption spectroscopySpectroscopyMicrochemical Journal
researchProduct